A technician checking motor insulation with a digital megaohm meter and leads on a workbench.

Best Megaohm Meters for Insulation Testing

As an Amazon Associate we earn from qualifying purchases. Details

Megaohm meters help you check insulation resistance in motors, cables, appliances and HVAC equipment before a failure causes a trip or shock risk. This guide compares seven insulation testers that state megohm measurement in their listings. You will learn what test voltage and range you need, what CAT and safety markings mean, and which meter fits motor, HVAC or general troubleshooting work. Work on mains circuits can kill. The meter CAT rating must suit the circuit. Panel or service work belongs to a licensed electrician.

Quick answer

If you want one meter that also works as a daily multimeter, start with the AIOMEST insulation multimeter or the Fluke 1577 insulation multimeter. Both listings state true RMS AC measurement and insulation testing at 500V and 1000V, which covers many motor and cable checks. For simple HVAC compressor and motor checks, the two M500 style testers from Iexcauw and ToolSentryX state 500V output and measurement up to 1000 megohms. For selectable low to mid test voltages, the WapoRich listing states 250V, 500V and 1000V with measurement up to 200MΩ. For higher resistance readings, the UNI-T UT501A and AOPUTTRIVER AP-6688B listings state wider insulation ranges. Always follow the instrument manual and local electrical rules.

What matters for megaohm meters

A megaohm meter applies a DC test voltage and reads leakage through insulation. A higher reading in megohms usually means better insulation. A low reading can mean moisture, dirt, heat damage or aged insulation. You are not measuring ordinary low ohms. You are checking whether insulation still isolates conductors.

Test voltage matters first. The listings here state 250V, 500V, 500V and 1000V, 550V and 1000V, or up to 5000V options. Use only the voltage allowed by the equipment maker. Never test electronics, control boards or low-voltage components at a voltage that can damage them. Check the equipment manual before you test.

Maximum range matters second. The picks state up to 200MΩ, up to 600 megaohms, up to 1000 megohms, up to 2000MΩ, or up to 200GΩ. Choose a range that covers the pass level in the equipment manual. If your motor maker calls for a high pass value, a 200MΩ ceiling may not be enough. Check the listing for the exact range.

Safety markings matter third. Some listings state IEC, CAT III 600V, CAT III installations, CAT II, CE, UL 61010-1 or IEC 61010 standards. When no CAT rating appears in the listing, do not treat the meter as safe for household mains. Measurement category is a method of classification by the International Electrotechnical Commission of live electric circuits used in measurement and testing. The categories take into account the total continuous energy available at the given point of the circuit and the occurrence of impulse voltages. Learn more in Best Megger Meters and Insulation Meters.

Usability matters fourth. Look at display counts, live-circuit lockout, guard terminal, backlight, data hold, NCV and included leads. Live circuit detection that prevents an insulation test when voltage is present adds protection against a wrong setup. A guard terminal can help on dirty or damp surfaces when the listing provides one.

Meter function matters fifth. Some picks are insulation-only testers with a simple Good, Caution or Bad scale. Others are full insulation multimeters with volt, continuity, capacitance or temperature functions. If you already own a trusted Best Volt Ohm Meters model, a simple tester may be enough. If you want one case for many checks, a combination meter saves space.

Top picks by situation

  • Best combination meter with wide functions: AIOMEST model T7-VC4060-B1
  • Best simple HVAC tester with LED result: Iexcauw model M500
  • Best documented insulation multimeter: Fluke model FLUKE-1577
  • Best simple tester with Good Caution Bad scale: ToolSentryX model M500
  • Best selectable 250V option: WapoRich model T6-VC60B
  • Best compact 1000V tester with auto shutoff: UNI-T model UNI-T UT501A
  • Best high-voltage and high-range option: AOPUTTRIVER model AP-6688B

1. Insulation Resistance Tester 1000V Megohmmeter w/TRMS Multimeter 2 in 1, AIOMEST Megaohm Meter w/IR (Best combination meter)

Specs from the listing (checked 2026-10-10):

  • Brand: AIOMEST
  • Model: T7-VC4060-B1
  • Specification Met: Iec, Cat III 600v
  • Compatible Devices: Motors, Pumps, Control Boards, HVAC Systems, Automotive Electrical Systems, etc.
  • Included Components: Megohmmeter

Pros

  • States insulation tests at 500V or 1000V up to 2000MΩ
  • States True RMS with 6000-Count Display and 20A current
  • States capacitance up to 60mF, inductance up to 60H and K-type temperature probe included

Cons

  • Combination menus take longer to learn than a simple Good Bad tester
  • Needs 6x AA batteries included, so spares matter for field days

Best for: DIYers and facilities helpers wanting insulation plus full multimeter functions
Skip if: You want a simple pass fail tester without extra modes.

View on Amazon (affiliate link)

2. M500 Megohmmeter Insulation Tester, HVAC Compressor & ECM Motor Tester up to 1000 Megohms at 500V (Best simple HVAC pick)

Specs from the listing (checked 2026-10-10):

  • Brand: Iexcauw
  • Model: M500
  • Style: M500 INSULATION TESTER MEGOHMMETER
  • Specification Met: CE, UL
  • Included Components: M500 Megohmmeter

Pros

  • States up to 1000 megohms at 500V for compressors and motors
  • LED indicators give fast status without manual analysis
  • Comes with test leads and heavy-duty carrying case

Cons

  • No CAT rating is shown in the listing fields
  • Uses 2 C batteries not included

Best for: HVAC helpers needing quick compressor insulation checks
Skip if: You need selectable voltages or a stated CAT rating.

View on Amazon (affiliate link)

3. Fluke 1577 Insulation Multimeter, LCD Display, 600 Megaohm Resistance, 500/1000V Voltage (Best documented safety)

Specs from the listing (checked 2026-10-10):

  • Brand: Fluke
  • Model: FLUKE-1577
  • Item Weight: 1 kg
  • Compatible Devices: Motors, Generators, Cables, Switch Gear, Linear Loads, Nonlinear Loads
  • Included Components: INSULATION MULTIMETER

Pros

  • States 0.1 to 600 megaohms with 550V and 1000V tests
  • Blocks insulation test when voltages over 30V are detected
  • Lists Category III installations with UL and IEC standards

Cons

  • 600 megaohms ceiling is lower than 1000 megohm and higher picks
  • Listed size 14.17 x 18 x 4.13 inches and 1 kg is bulky to carry

Best for: Readers who want documented standards and live-circuit lockout
Skip if: You need readings above 600 megaohms or a pocket-size tool.

View on Amazon (affiliate link)

4. M500 Megohmmeter Insulation Tester, 500V Digital Megger Meter Measures Up to 1000 MΩ, Portable HVAC (Easiest analog readout)

Specs from the listing (checked 2026-10-10):

  • Brand: ToolSentryX
  • Model: M500
  • Compatible Devices: Electrical devices and systems
  • Manufacturer: ToolSentryX
  • Part Number: M500

Pros

  • States up to 1000 MΩ at stable 500V output
  • Good, Caution, and Bad analog zones need no interpretation
  • Double-layer ABS enclosure resists impact and drops

Cons

  • No CAT rating is named in the provided fields
  • Single 500V output with no lower or higher voltage choice

Best for: Beginners wanting a clear analog Good Caution Bad result
Skip if: You need a digital value, more voltages, or mains CAT marking.

View on Amazon (affiliate link)

5. Megaohm Meter 1000V, Megohmmeter Insulation Resistance Tester (Best 250V option)

Specs from the listing (checked 2026-10-10):

  • Brand: WapoRich
  • Model: T6-VC60B
  • Specification Met: Ul 61010-1, Iec 61010-2-030, Ce Marked, Rohs Compliant
  • Item Weight: 580 g
  • Included Components: T6-VC60B

Pros

  • States 250V/500V/1000V selection up to 200MΩ
  • States DC to 1000V, AC to 750V and 2KΩ continuity with buzzer below 50Ω
  • 1999-count backlit LCD with Data Hold and compact 6.9×4.6×2.5 in size

Cons

  • 200MΩ ceiling is the lowest in this roundup
  • Listing avoids CAT II or CAT III wording in the fields given

Best for: Appliance and wiring checks where 250V testing is specified
Skip if: Your manual requires values above 200MΩ.

View on Amazon (affiliate link)

6. UNI-T UT501A Megohmmeter, Insulation Tester 1000v, Will Accurately Measure Insulation Values up (Best compact 1000V tester)

Specs from the listing (checked 2026-10-10):

  • Brand: UNI-T
  • Model: UNI-T UT501A
  • Item Weight: 0.6 kg
  • Item Dimensions: 5.91 x 3.94 x 2.8 inches
  • Specification Met: CE, RoHS

Pros

  • States up to 1000V testing for motors, cables and transformers
  • Maximum display 9999 with auto backlight for dark cabinets
  • Auto off after 10 minutes with low-battery warning and red HV lamp

Cons

  • CAT rating is absent from the listing fields shown
  • No multimeter current or capacitance modes stated

Best for: Maintenance users wanting a small 1000V insulation tester
Skip if: You need a stated CAT rating or combination meter functions.

View on Amazon (affiliate link)

7. Megohmmeter 200GΩ Electrical Megaohm Meter 5000V Testing Voltage (Best high-range option)

Specs from the listing (checked 2026-10-10):

  • Brand: AOPUTTRIVER
  • Model: AP-6688B
  • Item Weight: 900 g
  • Compatible Devices: motors, cables, transformers, high-voltage switches
  • Part Number: AP-6688B

Pros

  • States 1MΩ to 200GΩ with 500V to 5000V selection
  • GUARD terminal helps reduce surface leakage errors
  • 1999-count auto-ranging LCD with data hold and 6x AA batteries included

Cons

  • High voltages demand training; not for beginners or panels
  • States overvoltage category II only, so check circuit suitability

Best for: Trained users testing high-resistance motors, cables and switches
Skip if: You never need 2500V or 5000V, or need CAT III or IV.

View on Amazon (affiliate link)

Picks: detailed notes

AIOMEST insulation multimeter T7-VC4060-B1

This pick suits a DIYer or facilities helper who wants insulation testing plus daily multimeter functions in one case. The listing describes a 2 in 1 insulation tester with TRMS multimeter functions, including volt, 20A current, capacitance, inductance and continuity. The listing states insulation tests at 500V or 1000V with a measurement range up to 2000MΩ. The listing states True RMS technology, a 6000-Count display, AC voltage up to 750V and DC voltage up to 1000V. For HVAC and motor work, the listing states capacitance up to 60mF, inductance up to 60H, and temperature from -40°C to 1000°C with the included K-type thermocouple. The listing states IEC safety standards, overload protection with fuses, NCV detection, test leads, alligator clips, carrying case and 6x AA batteries. The listing states Specification Met Iec, Cat III 600v. Who should skip it: skip if you want a simple pass or fail tester, or if you do not need capacitance, inductance and temperature functions.

Iexcauw M500 insulation tester

This pick suits HVAC helpers and homeowners who want a simple dedicated tester for compressors and motors. The listing calls it an M500 Megohmmeter Insulation Tester for HVAC compressor and motor testing up to 1000 Megohms at 500V DC. The bullets describe use on motors, refrigeration compressors, control boards, transformers and air conditioning equipment. The listing uses intuitive LED indicators for status results, which can speed a routine check. The listing states battery-operated design using 2 C batteries, not included, plus a heavy-duty carrying case and test leads. The listing states Specification Met CE, UL. No CAT rating appears in its listing fields, so do not assume mains suitability from CE or UL alone. Who should skip it: skip if you need selectable test voltages, a numeric display range above 1000 megohms, or a stated CAT rating for mains circuits.

Fluke 1577 insulation multimeter

This pick suits a reader who wants documented safety and measurement standards from the listing. The listing states insulation measurement range of 0.1 to 600 megaohms with insulation test voltages of 550V and 1000V. It is described for testing line insulation on motors, generators, cables and switch gear. The listing states True RMS meter for linear or nonlinear loads. The listing states live circuit detection that prevents insulation test when voltages over 30V are detected. That lockout helps prevent testing a live circuit by mistake. Safety listings stated include IP40, CE, UL 61010 1, ANSI/ISA S82.01 2004, CAN/CSA C22.2 No. 1010.1:2004, IEC 61010 1 and IEC 61557 parts, plus Category III installations. The listing states Item Weight 1 kg and Item Dimensions 14.17 x 18 x 4.13 inches. Who should skip it: skip if you need readings above 600 megaohms, or if size and weight matter for tight field bags.

ToolSentryX M500 insulation tester

This pick suits a beginner who wants a clear analog result without interpreting digits. The listing states insulation resistance up to 1000 MΩ at a stable 500V output. The display uses Good, Caution and Bad zones on a clear analog scale. That format fits quick maintenance rounds on compressors, motor windings, transformers, panels and control circuits. The bullets mention detection of leakage, aging, moisture issues and thermal damage. The listing states a double-layer ABS enclosure for impact, abrasion and drop resistance. It includes a soft carrying pouch and is described as compact and portable. Its provided fields name no CAT rating, display counts, or battery type. Check the product listing for power, leads and manual details. Who should skip it: skip if you need a digital readout, selectable voltages, or a stated CAT rating.

WapoRich T6-VC60B megaohm meter

This pick suits appliance, wiring and general equipment checks where 250V testing is useful. The listing states selectable DC 250V, 500V and 1000V test voltages with insulation measurement up to 200MΩ. Lower test voltage can fit sensitive checks where the equipment maker limits voltage, but always confirm in the equipment manual. The listing also states DC up to 1000V and AC up to 750V with 1V resolution and 1MΩ input impedance. Resistance range is 2KΩ with 1Ω resolution, with buzzer below 50Ω for continuity. The listing states 1999-count LCD backlit display with sampling rate around 3 times per second, plus Data Hold. The listing states compact size 6.9 x 4.6 x 2.5 in and weight around 1.3 lbs with batteries. The listing states Specification Met Ul 61010-1, Iec 61010-2-030, Ce Marked, Rohs Compliant. The listing does not use the words CAT II or CAT III in the fields given. Who should skip it: skip if you need readings above 200MΩ.

UNI-T UT501A insulation tester

This pick suits equipment maintenance where a compact 1000V tester is needed. The title states insulation testing up to 1000V. The bullets state measurement of insulation resistance of transformers, motors, cables, switches and electrical appliances. The listing states Item Dimensions 5.91 x 3.94 x 2.8 inches, Item Weight 0.6 kg, maximum display 9999, automatic backlight, low battery warning, and automatic shut down after 10 minutes without operation. It accepts standard banana plug test leads and ships with included test leads. The listing states a red warning light during high-voltage output. The listing states Specification Met CE, RoHS. Because its listing fields name no CAT rating, do not treat it as rated for mains distribution work. See also Best Megaohm Tester before you decide between a compact tester and a full multimeter. Who should skip it: skip if you need a stated CAT rating, a guard terminal, or multimeter functions such as current and capacitance.

AOPUTTRIVER AP-6688B megohmmeter

This pick suits high-resistance checks on motors, cables, transformers and high-voltage switches where the equipment manual allows high test voltage. The listing states selectable test voltages of 500V, 1000V, 2500V and 5000V, with output maintained at 90 percent to 110 percent of rated value. It states insulation resistance from 1MΩ to 200GΩ. That wide span exceeds the other picks here. The listing states 3-1/2 digit 1999-count auto-ranging LCD with automatic polarity and over-range indication, plus built-in AC voltage measurement. It has a dedicated GUARD terminal with small alligator clip to reduce surface leakage effects. The listing states shockproof, dustproof and moisture-proof structure with protective rubber case, plus HV red LED warning during output. It states Item Weight 900 g and battery power from 6x AA batteries included. It states compliance with IEC-1010 double insulation, overvoltage category II, pollution degree 2. Who should skip it: skip if you never test at 2500V or 5000V, or if CAT II does not suit your circuit.

Comparison table

Meter Test voltages stated Insulation range stated Display and extras stated Safety stated
AIOMEST T7-VC4060-B1 500V or 1000V Up to 2000MΩ 6000-Count display, True RMS, 20A current, capacitance up to 60mF, inductance up to 60H, temperature -40°C to 1000°C, NCV Iec, Cat III 600v, overload protection with fuses
Iexcauw M500 500V AC output described Up to 1000 megohms LED indicators, test leads, carrying case CE, UL; no CAT rating shown in those listing fields
Fluke FLUKE-1577 550V and 1000V 0.1 to 600 megaohms True RMS, live circuit detection over 30V, Item Weight 1 kg Category III installations, UL 61010 1, IEC 61010 1, IEC 61557 1 and 2
ToolSentryX M500 500V output Up to 1000 MΩ Good Caution Bad analog scale, ABS enclosure, soft pouch No CAT rating named in the fields provided
WapoRich T6-VC60B 250V, 500V, 1000V Up to 200MΩ 1999-count backlit LCD, Data Hold, DC up to 1000V, AC up to 750V, 2KΩ resistance Ul 61010-1, Iec 61010-2-030, Ce Marked
UNI-T UT501A Up to 1000V Title states up to 1000 Megohms Maximum display 9999, auto backlight, auto off after 10 minutes, Item Weight 0.6 kg CE, RoHS; CAT rating absent from the listing fields
AOPUTTRIVER AP-6688B 500V, 1000V, 2500V, 5000V 1MΩ to 200GΩ 1999-count auto-ranging LCD, GUARD terminal, Item Weight 900 g IEC-1010 double insulation, overvoltage category II

How to choose megaohm meters

Start with the equipment manual. It may set the test voltage, minimum insulation value and test time. A motor manual may ask for 500V. An appliance manual may limit you to 250V or 500V. High-voltage gear may call for 1000V or more. Never exceed the maker limit. Related reading: Best High Voltage Meters and Fluke 1587 Fc Insulation Test.

Match test voltage to the job. For general motors, pumps and cable checks, 500V covers many routine tasks when the manual allows it. A 250V setting helps where low-voltage insulation or electronics are nearby. A 1000V setting fits larger motors and longer cable runs when specified. Voltages at 2500V and 5000V belong to trained users working under proper rules and permits. Beginners should not use them on building wiring or panels.

Match range to the pass value. If the manual requires a high minimum, a meter that stops at 200MΩ may show over-range when you need a number. A meter that reads to 1000 megohms, 2000MΩ or 200GΩ keeps headroom. Also note accuracy statements. The WapoRich listing states plus or minus 4.0 percent of reading plus 2 digits for insulation. Small differences matter when you trend readings over time.

Check CAT and voltage ratings before touching anything near mains. Measurement category IV is for measurements performed at the source of the high-voltage installation. Measurement category II is for measurements performed on circuits directly connected to the low-voltage installation. The required impulse withstand voltage varies from 500 V to 12,000 V across categories and voltages. Use a meter whose CAT and voltage marking suits or exceeds the point you will test. Where a listing omits the CAT rating, treat it as not shown and select a different meter for mains work.

Decide between simple tester and insulation multimeter. A simple tester gives fast insulation results with little setup. An insulation multimeter adds AC and DC volts, continuity, and sometimes current, capacitance or temperature. If you service HVAC systems, capacitance up to 60mF and temperature with a K-type probe can reduce tools in the bag. If you only check compressors each season, a simple M500 style meter is easier to learn.

Look at leads, guard terminal and display. Detachable leads with alligator clips help on motor terminals. A neck strap or shoulder strap helps on ladders. Backlight and data hold help in dark cabinets. A guard terminal helps when humidity or dirt creates surface leakage. For background on current clamps versus insulation testers, see How Do Clamp Meters Work.

Planning example with our numbers

This example shows how range choice changes what you learn. It is our planning estimate, not a test result and not a pass standard.

Suppose you maintain three small motors. The maker manual sets a minimum of 50 megohms at 500V for each motor. You plan one reading per motor per season, for four seasons.

Define the values:

  • Planned test voltage = 500V
  • Minimum pass value = 50 megohms
  • Number of motors = 3
  • Readings per year = 4 per motor
  • Total readings per year = 3 x 4 = 12 readings

Now compare meter ceilings:

  • Meter A ceiling = 200MΩ
  • Meter B ceiling = 1000 megohms
  • Headroom for Meter A = 200 – 50 = 150 megohms above minimum
  • Headroom for Meter B = 1000 – 50 = 950 megohms above minimum
  • Extra headroom with Meter B = 950 – 150 = 800 megohms

Re-check: 3 x 4 = 12. 200 – 50 = 150. 1000 – 50 = 950. 950 – 150 = 800. All steps use the same units.

What this means: both meters can show whether you pass 50 megohms. Meter B gives more room to track drying or aging trends well above the minimum. If your manual required 100 megohms or 500 megohms, the 200MΩ ceiling would leave less room. Choose range based on the manual value, not on headline voltage alone. For related ohm basics, see Best Ohm Meter.

Five common mistakes

De-energizing wrong. Never run an insulation test on a live circuit. Disconnect power, lock out where required, verify absence of voltage with a suitable volt function, then connect the megaohm meter. The Fluke 1577 listing states it blocks insulation tests when voltage over 30V is present. Do not rely on that feature alone. Beginners should avoid panels, meters bases and service gear entirely.

Using the wrong test voltage. A 1000V test on a 250V rated control circuit can puncture good insulation. Read the nameplate and manual first. If the manual is missing, ask the maker or a licensed electrician. Do not guess.

Testing connected electronics. Disconnect drives, controls, surge devices and sensitive loads before insulation testing, as the equipment manual directs. High DC test voltage can damage parts that are still connected. If you are unsure what is connected, stop and get help.

Ignoring surface leakage. Dust, oil and moisture can pull a reading down. Clean and dry the terminals, separate leads, and use a guard terminal when the meter provides one. The AOPUTTRIVER listing includes a GUARD terminal for this reason. Record temperature and humidity notes with each reading when trending.

Calling any meter mains-safe. A CE mark alone is not a CAT rating. UL or IEC numbers matter only when the listing ties them to a CAT and voltage. IEC 61010-1 requires that the transient withstand capability of the equipment is made known to the user. Where the fields show no CAT rating, avoid using that meter on household mains. Check the product listing and manual.

Care and safe use

Store leads dry and untangled. Inspect probes, clips and jackets for cracks before each use. Replace damaged leads with the type the maker specifies. Remove batteries for long storage if the manual advises it.

Discharge the circuit after an insulation test. Capacitive equipment can hold charge. Follow the manual discharge and wait time. Keep hands off terminals during the test and heed any red high-voltage lamp or tone.

Do not open the meter case or change fuses with power connected. The AIOMEST listing states overload protection with fuses. Fuse type and current matter for safety. Use only the maker-specified part.

Automotive notes: disconnect and handle batteries safely. Keep sparks away from vents. Never probe airbag wiring or high-voltage hybrid and EV systems. Those jobs need special training and tools.

When in doubt, stop. This article cannot replace the manual or a licensed electrician. For continuity basics that pair with insulation work, see Best Continuity Meters.

FAQ

What does a megaohm meter do?

It applies a DC test voltage and measures resistance through insulation. The result reads in kilohms, megohms or gigohms. High values suggest intact insulation. Low values suggest moisture, contamination or damage. Always compare to the equipment maker minimum.

Is a megaohm meter the same as a regular ohmmeter?

No. A standard ohmmeter uses low voltage for continuity and component checks. A megaohm meter uses higher DC test voltage, such as 250V, 500V or 1000V, to stress insulation. The two tools answer different questions. Many insulation multimeters include both functions.

What test voltage should I use?

Use the voltage in the equipment manual. Many motor and cable manuals specify 500V. Some small appliances specify 250V. Larger or high-voltage gear may specify 1000V or more. Using too high a voltage can damage insulation or electronics. If you cannot find a value, ask the maker or an electrician.

Do I need true RMS in a megaohm meter?

True RMS matters for the multimeter side, not for the insulation resistance reading itself. True RMS gives more accurate AC voltage or current on distorted waveforms from drives or nonlinear loads. The AIOMEST and Fluke listings here state True RMS. If you only need insulation readings, it matters less.

What do counts mean on these displays?

Counts describe display resolution in simple terms. A 1999-count display can show up to 1999 steps on its range before changing range. A 6000-count display can show finer steps. Counts do not equal accuracy. Read the accuracy statement and range in the listing.

Can a beginner test house wiring with these meters?

Beginners should avoid live panels, breakers and service equipment. Work on mains circuits can kill. Practice first on de-energized training boards, cords or motors under supervision, with the manual open. When a listing shows no CAT rating, avoid household mains use with that meter. Hire a licensed electrician for panel work.

Why did my reading start low then climb?

Insulation and cable capacitance can charge during the test, so the number may rise before it steadies. Moisture drying under voltage can have a similar effect. Follow the manual test time, keep leads still, and record the settled value plus test voltage. Compare trends at the same voltage and conditions.

Bottom line

Choose by manual voltage, range headroom and stated safety rating. Choose the AIOMEST combination meter if you want insulation plus full multimeter functions and a stated CAT III 600V marking. Choose the Fluke 1577 if you want documented standards and live-circuit lockout above 30V. Choose an M500 style tester if you want simple HVAC checks up to 1000 megohms. Choose WapoRich if you need a 250V setting with a 200MΩ ceiling. Choose AOPUTTRIVER only if your work truly needs 2500V or 5000V and CAT II suits the circuit. If no listing shows the CAT rating your circuit needs, do not buy for mains work.