This page explains how to check smd inductor with multimeter in five short steps. Set the meter to its lowest resistance range, touch the probes to the two soldered ends of the part, and read the winding’s resistance. A healthy inductor should read a very low value. An open winding reads high or infinite, and a reading of 0.0 ohms can point to coils touching inside the part. A multimeter cannot confirm inductance, so a low reading shows the winding is intact rather than proving the part’s value. This how-to covers the steps, how to read the beep, and what the meter cannot tell you about an SMD inductor.

Quick answer

  • Power the circuit off before you measure.
  • Set the multimeter to ohms, using the lowest range the meter offers.
  • Touch one probe to each end of the inductor’s pads and read the number.
  • A very low, steady reading is what a healthy coil should show. An infinite reading suggests an open winding.
  • Do not rely on the beep alone, and use an LCR meter to check the inductance value.

What you need

You need a digital multimeter with a resistance function and a fine-tip pair of probes. A small SMD part can slip under a wide probe tip, so a fine tip makes it easier to reach both pads. You also need the schematic or the part number, so you know which inductor you are checking. The PCIM article on testing inductors describes the same basic tool: “Set the multimeter to Ohmic mode. Use the lowest resistance range.” Its procedure relies on a meter that can read small resistances, so choose a meter that offers a low ohms range.

Step 1: Power off and isolate the part

The SparkFun continuity tutorial says that “continuity should be tested with the system turned off.” That rule applies to an inductor on a board as much as to any other continuity test. A live circuit can feed current into the reading and give a false result. If the circuit has capacitors, let them discharge before you probe, because the SparkFun page notes that “Capacitors will act like a short for a split second until they fill up with energy, and then act like an open connection.”

Where possible, lift one end of the inductor from the board before you measure. Parallel paths through other components can change the reading. A resistance that looks low may come from the rest of the circuit, not from the coil itself. If you cannot lift a pad, keep that in mind when you judge the number.

Step 2: Set the meter and probe the pads

Turn the dial to the ohms position. The Industrial Monitor Direct guide advises that you “Set your multimeter to the lowest resistance range (typically 200Ω or 2kΩ).” Touch the probes to the two terminals of the inductor, one on each pad. Hold them steady, because a loose contact can show a false open reading. Note the number on the display before you move the probes.

Step 3: Read the number

The number tells you what the winding is doing. The PCIM article says that “healthy inductors have very low DC resistance” and that a healthy inductor should read only a few milliohms, which it describes as “typically less than 1 ohm.” A reading in that low range is what a sound winding should show. A reading that climbs toward infinity suggests the winding is broken, which the article calls an open circuit.

A reading of 0.0 ohms is different. The PCIM article says a short circuit “reads as 0.0 ohms, which indicates coils touching internally.” Treat a 0.0 ohms reading as a sign of an internal short, and replace the part if the circuit requires a working inductor.

Step 4: Understand the beep

Many meters have a continuity mode with a beep. The SparkFun tutorial describes the logic: “If there is very low resistance (less than a few Ωs), the two points are connected electrically, and a tone is emitted.” It also says that “If there is more than a few Ωs of resistance, than the circuit is open, and no tone is emitted.”

The Industrial Monitor Direct guide warns that “A common misconception is that a “beep” (continuity) reading on a multimeter indicates a shorted inductor.” A beep shows that the winding has low resistance, which is what a healthy coil should have. It does not confirm that the part is good. For an inductor, use the numeric ohms reading as the main result and treat the beep as a quick check.

Step 5: Know what the multimeter cannot tell you

The main limit of this test is inductance. The Industrial Monitor Direct guide says that “An open inductor (failed winding) requires LCR testing—multimeters cannot detect inductance.” The PCIM article says the same kind of thing in a different way: its procedure describes resistance checks that can reveal open or shorted windings, and it does not say a multimeter can confirm the inductance value.

So a multimeter can help you find a clear fault, such as an open winding or an internal short. It cannot tell you whether a part’s inductance matches the value printed on the schematic or the datasheet. For that, use an LCR meter or LCR tweezers, which measure inductance directly. A dedicated tester is the right tool when a low resistance reading looks normal but the circuit still misbehaves.

A simple workflow

  1. Confirm the power is off and the capacitors are discharged.
  2. Lift one end of the inductor if you can.
  3. Set the meter to the lowest ohms range and probe both pads.
  4. Record the reading. An infinite reading points to an open winding, and 0.0 ohms points to an internal short.
  5. If the reading is low and steady, check the inductance with an LCR meter if the circuit needs a specific value.

Where a multimeter fits in the toolkit

A standard meter is useful for finding faults in a board, but it is not a full component analyzer. For a general overview of what a meter can measure, read our guide to the best multimeters. If your work includes capacitors as well as inductors, how to test a capacitor with a digital multimeter covers the other common passive part and explains what a meter can and cannot show about it.

Electrical safety

Most SMD inductors sit on low-voltage electronics, but the board they are on may be connected to mains through a power supply. Do not probe a live mains circuit to check an inductor. Work on the board with the power removed, and keep mains work with a qualified person. If you need to measure a circuit at mains voltage, use a meter with a CAT rating that fits that circuit.

How we chose

We chose three sources that each explain resistance testing of an inductor or of continuity in a readable page. The SparkFun tutorial covers the continuity beep and the rule to test with power off. The Industrial Monitor Direct guide covers the lowest-range setting and the limits of a multimeter for inductance. The PCIM article covers open and shorted readings and the inductance limit. No product is recommended in this how-to.

What we could not verify

The three sources give the test procedure, the meaning of low, open and zero-ohm readings, and the limit that a multimeter cannot confirm inductance. They do not give a reliable typical resistance range for a given inductor. Two of the sources give different ranges for healthy values, and one of them gives a range for a 100 microhenry part only as an example. This guide does not quote those ranges as a rule, because the right value depends on the part’s datasheet. Check the datasheet for the DC resistance (DCR) of your inductor and compare the reading with that figure. The sources also do not cover every SMD package or in-circuit measurement method.

FAQ

Can a multimeter check an SMD inductor?

Yes, for a basic check. A multimeter on the ohms setting shows whether the winding is open or shorted. It cannot confirm the inductance value.

What does 0.0 ohms mean on an inductor?

The PCIM article says a short circuit reads as 0.0 ohms and indicates coils touching internally. Treat that reading as a fault.

Why does my inductor beep?

A healthy winding has low resistance, so it can trigger the continuity beep. The beep alone does not prove the part is good or bad.

Do I need to remove the inductor from the board?

Lifting one end gives a cleaner reading because other parallel paths on the board can change the result. If you cannot lift it, read the number with that limit in mind.

What tool confirms inductance?

An LCR meter or LCR tweezers measures inductance directly, according to the Industrial Monitor Direct guide.

Sources

  • SparkFun Learn, How to Use a Multimeter: Continuity. https://learn.sparkfun.com/tutorials/retired—how-to-use-a-multimeter-/continuity (opened 2026-10-29)
  • Industrial Monitor Direct, SMD Inductor Identification: Reading Markings and Testing Guide. https://industrialmonitordirect.com/blogs/knowledgebase/smd-inductor-identification-reading-markings-testing-guide (opened 2026-10-29)
  • PCIM, How to test an inductor. https://news.pcim.mesago.com/how-to-test-an-inductor-a-e6b3f174732bc4dd26686e1b4199d945/ (opened 2026-10-29)