What the Hioki CM4372 Clamp Meter Does and Its Discontinued Successor
What the Hioki CM4372 Clamp Meter Does and Its Discontinued Successor
As an Amazon Associate we earn from qualifying purchases.
The Hioki CM4372 is a true RMS AC/DC clamp meter rated to 600 A, with Bluetooth for sending readings to a phone or tablet. Hioki designed it for electric vehicle, equipment and solar work, and it lists an IP54 dustproof and waterproof enclosure. Hioki’s India product page marks the CM4372 as discontinued and names the CM4371-50 as its replacement. This guide explains what the CM4372 does, how it is rated, and where the sources differ on its DC voltage range.
Quick answer
- The CM4372 is a 600 A true RMS AC/DC clamp meter with Bluetooth and an IP54 enclosure.
- Hioki’s product page marks it as discontinued and names the AC/DC CLAMP METER CM4371-50 as the replacement.
- Hioki says the meter measures DC voltage up to 1700 V with conditions. The distributor page lists a DC voltage range up to 1500 V, so check the manual for the rating on your unit.
How we chose
We chose two sources that we opened and read. The first is Hioki’s India product page for the CM4372, because it is the manufacturer’s own statement and it includes the discontinued status. The second is the ITM product page, which lists a full specification block. We did not use search snippets, prices, stock levels, or customer reviews. We did not use other Hioki clamp pages as a source for the CM4372.
What Hioki says about the CM4372
Hioki describes the CM4372 as “a 600A True RMS clamp meter that features stronger jaws, broader -25°C to 65°C operating temperature range and IP54 dustproof and waterproof enclosure.” The page says the meter is meant for development, repair and maintenance of equipment such as electric vehicles. It lists these features:
- Sending measured values to a smartphone or tablet using Bluetooth wireless technology, with waveforms shown in real time.
- Multiple measurement functions and an automatic AC/DC function.
- Simultaneous measurement of inrush current in RMS and crest values.
- An IP54 dustproof and waterproof enclosure.
- An operating temperature range of -25°C to 65°C.
Hioki says the jaws, which are the current sensor portion, carry an IP50 rating. The page says data can be downloaded to a tablet or smartphone with the free app GENNECT Cross, which is available from the Google Play and App Store.
Safety ratings and the DC voltage note
Hioki lists the safety ratings as “CAT IV 600 V, CAT III 1000 V.” The same page gives a high-voltage DC measurement of up to 1700 V and adds a condition: the instrument may be used above 1000 V DC only when the circuit is isolated from the commercial power grid and from ground. Hioki’s example is the no-load voltage of an ungrounded PV panel. The page also states that the instrument should not be used on circuits whose terminal-to-ground voltage exceeds 1000 V, because that may cause electric shock.
Read that note before you use the meter on a solar array or any DC system. The 1700 V figure is not a general-purpose rating. It applies only under the isolation conditions Hioki states.
What the distributor page lists
The ITM page gives these specifications in the text we read:
- AC and DC current, each listed as “20/600 A,” with “±1.3% of reading ±0.08A basic accuracy (20 A range).”
- DC voltage of “600 mV to 1,500 V in 5 ranges,” with “±0.5% of reading ±0.5 mV basic accuracy (at 600 mV).”
- An IP rating of “IP54 dustproof and waterproof enclosure.”
- A safety rating of “CAT IV 600 V, CAT III 1,000 V.”
The ITM page also says the meter has been discontinued and names the CM4371-90 as the direct replacement. Hioki’s page names the CM4371-50. The two sources name different replacements. The Hioki page is the manufacturer’s statement, so this guide treats it as the reference for the replacement, and the difference is flagged here.
The DC voltage conflict
The Hioki page gives DC measurement up to 1700 V, with the isolation conditions above. The ITM spec block gives a DC voltage range up to 1,500 V in five ranges. The ITM feature list also mentions “DC voltages up to 1,700 V,” so the distributor page contradicts itself. We could not resolve the figure from the pages we opened. For any DC voltage work, read the rating in the manual for your order code and do not rely on a single figure.
Bluetooth and data logging
Hioki says the CM4372 sends measured values to a smartphone or tablet over Bluetooth, and that the GENNECT Cross app displays waveforms. The distributor page also describes waveform display and logging through the same app. These features are useful for recording inrush current or a load that changes over time. They depend on the phone or tablet and the app version, so confirm that your device runs the app before you buy.
Bluetooth is a convenience feature, and it does not change the meter’s measuring range or safety rating. Use the meter’s display for any reading you act on at the panel.
Frequently asked questions
Is the CM4372 still sold by Hioki?
Hioki’s India page marks the CM4372 as discontinued. Check Hioki’s current listing for stock and the exact successor for your region, because the ITM page names a different replacement.
Does the CM4372 measure DC current?
The ITM page lists AC and DC current, each in a 20 A and 600 A range. Hioki’s page describes the automatic AC/DC function. Use the manual to confirm the DC current range for your unit.
What is the 1700 V DC note?
Hioki’s page says the meter can measure up to 1700 V DC only when the circuit is isolated from the grid and from ground. It also says the meter should not be used on circuits with terminal-to-ground voltage above 1000 V.
Does the CM4372 work with a phone?
Yes. Hioki says it sends measured values to a smartphone or tablet over Bluetooth and uses the GENNECT Cross app to show waveforms.
Why do the sources name different replacements?
Hioki’s page names the CM4371-50, and the ITM page names the CM4371-90. We report the Hioki statement as the manufacturer’s reference and could not confirm the second source’s claim from Hioki.
Related reading
For background on how clamp meters sense current, see our guide on how a current clamp works. For a separate first check on live conductors, see our guide on Klein non-contact voltage detectors.
What we could not verify
- The two sources give different DC voltage ranges, and the distributor page contradicts itself on the 1500 V and 1700 V figures.
- The two sources name different replacement models.
- We could not confirm the battery type, battery life or the weight of the CM4372 from the pages we opened.
- The distributor page’s basic accuracy applies to the 20 A range only, and we could not check the other current ranges.
Bottom line
The Hioki CM4372 is a discontinued 600 A AC/DC clamp meter with Bluetooth and an IP54 enclosure. Confirm the DC voltage rating and the replacement model with Hioki before you buy, and follow the isolation conditions on the 1700 V DC note.
Sources
- Hioki, AC/DC CLAMP METER CM4372 (Bluetooth) product page (India): https://www.hioki.com/in-en/products/clamp-meters/ac-dc-clamp/id_6594 (opened 2026-10-30)
- ITM, Hioki CM4372 AC/DC Clamp Meter, 20 to 600A: https://www.itm.com/product/hioki-cm4372-ac-dc-clamp-meter (opened 2026-10-30)