What a Fluke Dry Block Calibrator Does and How It Is Used

As an Amazon Associate we earn from qualifying purchases.

A dry block calibrator, also called a dry well, is a portable heated or cooled metal block used to check the accuracy of temperature sensors and thermometers. Fluke makes dry block calibrators, and two of its models, the 9103 and the 9140, are named in the sources we opened. This guide explains how the device works, what the sources say about the two models, and what they do not say about temperature range.

Quick answer

  • A dry block calibrator heats or cools a metal block to a set temperature, and you insert a sensor into a hole in the block to compare its reading with the calibrator’s display.
  • Fluke’s learning article describes the calibrator as reaching very low to very high temperatures depending on the model, without giving a figure.
  • The dealer page names the 9103 and 9140 models with ±0.25 °C accuracy and an RS-232 interface, but it gives no operating temperature range for either model.

How we chose

The keyword is a product family rather than one model, so we opened two pages. One is a Fluke learning article that explains how dry block calibrators work. The other is a dealer page that describes Fluke’s 9103 and 9140 units. The dealer page is not a manufacturer page, so we treat its figures as a reseller’s summary. We did not use search snippets, prices or ratings.

What a dry block calibrator is

The Fluke learning article defines a dry-block calibrator as a tool for calibrating temperature measurement devices. It uses a dry well instead of a liquid bath to provide a stable and uniform temperature source. The article says the device works by heating or cooling a metal block to a precise temperature. A sensor is placed in one of the pre-drilled holes, its reading is compared with the calibrator’s display, and the sensor or its display is adjusted to match.

The learning article contrasts the dry well with a liquid bath in its name and in its description of a dry, uniform source. The sources we opened do not compare the two methods in detail, so this guide does not make a broader claim about which is better for a given job.

The temperature range question

The learning article says a dry block can reach very low to very high temperatures, depending on the model and its intended use. It does not give a number. The dealer page does not give an operating range for the 9103 or the 9140 either. The two sources therefore agree that the range depends on the model, but neither gives a figure we can quote.

For a calibration job, the range is the first thing to confirm. Check the target temperature against the model’s stated range in the Fluke datasheet before you plan the work. Do not assume a range from the phrase very low to very high.

The Fluke 9103 and 9140

The dealer page describes the two units as lightweight and portable. It gives an accuracy of ±0.25 °C for both, an RS-232 interface, and easy recalibration. The units can be checked for thermal switch actuation, which is a use the page names specifically. The page says the heating and cooling rates can be adjusted from the front panel.

The page also says that multiple-hole inserts are available for different probe sizes. The insert choice matters because a sensor that does not fit the hole does not make good contact with the block, and the reading will not reflect the block’s temperature. Choose the insert that matches the sensor diameter.

The dealer page states that each unit is factory-tested and ships with a NIST-traceable calibration report at no extra charge. That is a useful detail for a lab that needs traceability, but the page does not explain the traceability chain in detail. Check the report that comes with the unit you buy.

Step-by-step: a basic sensor check

  1. Place the calibrator on a stable, level surface away from draughts, and set the target temperature.
  2. Allow the block to reach the set temperature and hold it until the display is steady.
  3. Insert the sensor into the hole with the insert that fits its diameter, and let it settle.
  4. Compare the sensor reading with the calibrator’s display.
  5. Record the difference, and adjust the sensor or its display only if your procedure allows it.

The learning article describes the comparison and adjustment steps. The dealer page adds the insert and the front-panel rate controls. The settling time and the stability criteria are not in the sources, so use your site or lab procedure for those.

Safety and handling

The block is hot or cold during use, and it stays that way after the set point is changed. Allow it to reach a safe temperature before you handle the block or the inserts. The sources do not give a handling temperature, so check the manual for the safe-touch limit of your unit.

What to check on the unit you buy

Because the sources give no temperature range for either model, check a short list of items before a calibration job. Confirm the model number, since the dealer page names the 9103 and the 9140 and the sources do not give their ranges. Confirm that the insert set matches your sensor diameters, since the dealer page says inserts are available for different probe sizes. Confirm the RS-232 interface if you plan to log readings, since the dealer page names it. Confirm that a NIST-traceable calibration report comes with the unit, since the dealer page says one does.

The learning article says a dry block can reach very low to very high temperatures. A sensor you test may still sit outside the block’s useful range, so check that the sensor’s own rating covers the temperatures you plan to test.

What we could not verify

  • The operating temperature range for the 9103 and 9140 is not stated in the sources we opened.
  • The dealer page’s statement that the units beat every comparable dry block in performance, size and weight is a reseller’s claim, and we do not repeat it.
  • The settling time, the stability criterion and the heating and cooling rates are not given as numbers in the sources.
  • We did not read the Fluke datasheet or the manual for either model, so the figures above come from the two pages.

FAQ

What does a dry block calibrator check?

It checks temperature sensors and thermometers by comparing a sensor’s reading with the temperature of a heated or cooled block.

Which Fluke models do the sources name?

The dealer page names the 9103 and the 9140. Both are described with ±0.25 °C accuracy and an RS-232 interface.

What temperature range can it reach?

The learning article says it depends on the model and gives no figure. The dealer page gives no range for either model. Check the datasheet for the unit you plan to use.

Do I need a special insert?

The dealer page says multiple-hole inserts are available for different probe sizes. Choose the insert that matches your sensor’s diameter.

For related reading on this site, see our multimeter guide and our article on handheld digital multimeters.

Bottom line

A Fluke dry block calibrator heats or cools a metal block so you can check a sensor against a stable reference. Confirm the temperature range, the insert and the traceability report for your model before you plan a calibration.