As an Amazon Associate we earn from qualifying purchases. Details
Soil resistance testing usually means checking an earth electrode or ground rod, and the three listings below are the earth ground resistance testers in our research set that name a soil resistivity function. Each listing states its own resistance range, test method and voltage inputs, and we show those figures as the sellers give them. The listing data was checked on 2026-10-18 for the extra products and on 2026-10-11 for the research set. Read the method line before you buy, because a ground resistance check and a soil resistivity check are not the same test.
Quick answer
If the test you need is a four-pole soil resistivity measurement, the INFURIDER-labeled tester (B0DRP47R39) is the only one of the three whose listing states that method and a soil test range. The VIVANTECH VA115 (B0GVMWSYH6) and the DUOYI DY4100B (B0GTW385R3) name a soil resistivity function in the title but give fewer details. For a plain earth ground check, compare the resistance range and the voltage inputs first, then confirm the included parts on the live listing.
The three testers at a glance
| Tester | ASIN | Resistance range (as listed) | Voltage inputs (as listed) | Soil function (as listed) |
|---|---|---|---|---|
| VIVANTECH Digital Ground Resistance Tester (VA115) | B0GVMWSYH6 | 0.03 to 2000 ohms (title) | AC ground voltage up to 600 V; DC solar voltage up to 1500 V | Named in title as a soil resistivity meter; no method given |
| DUOYI DY4100A / DY4100B Earth Ground Resistance Meg-ohmmeter | B0GTW385R3 | 0 to 2000 ohms (title) | Not stated in the bullets | DY4100B variant named as having a soil resistivity function |
| INFURIDER Earth Resistance Tester (YF-T0-DY4100-2-B) | B0DRP47R39 | 0.03 to 2000 ohms in four ranges | AC 0 to 600 V; DC 0 to 1500 V | Four-pole soil resistivity method; soil test range 0.2 to 3768 ohm-meters |
1. VIVANTECH Digital Ground Resistance Tester (VA115)
The listing gives the model as VA115 and the part number as VIDY4100A. Its bullets say the tester supports 2-wire and 3-wire methods, with a range up to 2000 ohms and an accuracy stated as plus or minus 3 percent. The same listing states AC ground voltage up to 600 V and DC solar voltage up to 1500 V. Its auto test mode is described as stopping when readings stabilize, with an OK or NG prompt. The listing also lists a backlit LCD, data hold, auto power-off, a low battery indicator, and a CAT III 600 V and CAT IV 300 V safety rating. The product weighs 3 pounds (about 1.4 kg after conversion) and measures 6.8 x 4.9 x 2.7 inches, according to the specification block, which also gives a maximum operating voltage of 1500 volts DC.
The listing gives a CAT III rating of 600 V and a CAT IV rating of 300 V, so check which category applies to your work before you rely on either figure. The listing mentions an auxiliary ground resistance warning and series interference voltage detection. Those two features matter when a ground rod sits close to other grounding paths, but the bullets do not say how the warning is triggered, so read the manual before you rely on it.

2. DUOYI DY4100A / DY4100B Earth Ground Resistance Meg-ohmmeter
This listing covers two variants, the DY4100A and the DY4100B, and the title says the DY4100B has a soil resistivity function. The bullets are short. They describe a large screen, a digital display, a third gear position for measurement, overload protection, and a protective cover made of thick material. The model is listed as QD-DY4100B, and the warranty is listed as one year.
The brand entries conflict. The brand is given as QDTimes, while the manufacturer is given as DUOYI. The listing does not state a voltage input or a test method in the bullets, so this is the thinnest entry of the three. Use it only if the brand and the variant match what you intend to buy.
3. INFURIDER Earth Resistance Tester (YF-T0-DY4100-2-B)
This is the only listing of the three that states a soil method in its bullets. It says the tester supports 3-wire and simple 2-wire measurements, and that the same unit can be used as a soil resistance tester to measure soil resistivity by the four-pole method. The listing gives four resistance ranges, 0.03 to 2 ohms, 0.03 to 20 ohms, 0.3 to 200 ohms and 3 to 2000 ohms, and two voltage ranges, 0 to 600 VAC and 0 to 1500 VDC. The soil resistance range is given as 2 to 2000 ohms, and the soil test range as 0.2 to 3768 ohm-meters, or 0.002 to 376.8 kilo-ohm-meters.
The bullets also describe a data hold that freezes the reading and shows an H on the display. If a hazardous voltage appears while the reading is held, the listing states that a warning prompt is shown. The LED backlight stays on for 30 seconds, and the unit auto powers off. The compatible devices field lists test cables, ground rods and AA batteries, while the included components field lists only the earth resistance tester. Check the box contents before you order if you need leads or rods. The specification block also gives a minimum operating voltage of 48 volts AC, a figure the bullets do not explain.

How we chose these three
We kept a product only when its listing names a soil resistivity function in the title or bullets, and when the listing gives a resistance range that can be compared with the others. We worked from listing text alone. We did not test any of these testers, and nothing below reports bench or field results.
- Function named: all three titles or bullets mention soil resistivity or soil resistance.
- Range given: each listing states a ceiling of 2000 ohms, so the three can be compared on the same top limit.
- Method stated: only the INFURIDER listing states the four-pole method and a soil test range.
The research set also included a plant moisture and soil kit, a multimeter, and a megohmmeter. Their titles describe moisture, general measurement or insulation work, so we left them out of a soil resistance comparison.
Worked example: choosing a range for a low ground reading
Take a reading of 0.5 ohms as an illustration only, not a measured value. The INFURIDER listing gives four ranges. The 0.03 to 2 ohm range and the 0.03 to 20 ohm range both cover 0.5 ohms. The 0.3 to 200 ohm range also covers it. The 3 to 2000 ohm range does not, because 0.5 ohms is below its 3 ohm floor. The sensible choice is therefore the 0.03 to 2 ohm range, which is the narrowest range that still covers the value.
Now take a reading of 2,400 ohms. The VIVANTECH listing states a top limit of 2000 ohms, and the INFURIDER listing gives the same 2000 ohm top for its highest range. A reading of 2,400 ohms would be above both listed limits, so the listings would not give a valid result for that value. That check takes less time than a failed test on site.
Where the listings disagree
The three listings do not describe the same figures in the same way, so they should not be read as interchangeable.
- Brand: the DUOYI listing gives the brand as QDTimes in its specification block and the manufacturer as DUOYI.
- Soil range: the INFURIDER listing gives a soil resistance range of 2 to 2000 ohms and a separate soil test range of 0.2 to 3768 ohm-meters. Those two numbers measure different quantities and should not be compared with each other.
- Lowest resistance: the VIVANTECH title gives 0.03 ohms as the low end, while the INFURIDER range set also starts at 0.03 ohms. The DUOYI title gives 0 ohms as the low end, which is not the same claim.
What the listings do not say
None of the three listings gives an accuracy figure for the soil function. The VIVANTECH accuracy of plus or minus 3 percent applies to the ground resistance measurement as written in its bullets. The DUOYI listing gives no accuracy at all. The listings also do not say how far apart the probes or rods must sit for a soil reading, and they do not give a probe length, so a soil survey plan needs a different source. Battery types are given for the INFURIDER listing (AA) but not for the other two. Warranty terms are given only for the DUOYI listing, as one year.
Frequently asked questions
Can an earth ground resistance tester also measure soil resistivity?
All three listings name a soil resistivity function. Only the INFURIDER listing states the four-pole method in its bullets, so that is the one whose soil claim can be checked against the text.
What resistance range do these testers cover?
Each listing states a top limit of 2000 ohms. The INFURIDER listing gives the widest detail, with four ranges from 0.03 to 2000 ohms.
Are test leads and ground rods included?
The INFURIDER listing names test cables and ground rods as compatible devices, but its included components field lists only the tester. The VIVANTECH and DUOYI bullets do not give a full parts list, so check the box contents on the live listing.
What voltage inputs do these testers accept?
The VIVANTECH listing gives AC ground voltage up to 600 V and DC solar voltage up to 1500 V. The INFURIDER listing gives 0 to 600 VAC and 0 to 1500 VDC. The DUOYI listing does not state a voltage input in its bullets.
Which tester should I choose for a soil check?
The listings do not rank the three. If the soil method matters to you, the INFURIDER listing is the only one that states it. If you need only an earth ground check and a stated voltage input, compare the VIVANTECH listing with the others on the same range.
Conclusion
The three listings in this set are earth ground resistance testers, and each one names a soil resistivity function. The INFURIDER listing gives the most method detail and the widest set of ranges. The VIVANTECH listing gives the clearest voltage and safety data. The DUOYI listing is the thinnest and has a brand conflict to resolve. The listing data is as checked on 2026-10-18 for these three products, so confirm the live listing before you buy.
For related reading, see best soil resistivity meter, best earth ground meter, and best earth ground resistance tester.
VIVANTECH VA115 on Amazon · DUOYI DY4100B on Amazon · INFURIDER earth resistance tester on Amazon