An earth tester meter measures the resistance of a grounding path, and most listings in this category are sold as ground resistance testers rather than general meters. The three products below are the only earth ground testers in our research set with listing data. They are all sold under the VIVANTECH brand, so this page compares three models from one maker, not three competing brands. Listing figures were checked on 2026-10-18. Read each product’s resistance range and voltage limit side by side, because the three listings do not give the same earth voltage figure.
Quick answer
If you need a clamp that reads ground loops without disconnecting leads, the clamp model (B0GRVC6XGY) is the only one whose listing describes that method. If you need the widest resistance range, the rod-type VA115 (B0GVMWSYH6) and the kit (B0FMX9MT7L) both state a top limit of 2000 ohms. If you need an earth voltage reading capped at 30 V AC, the kit lists that figure, while the VA115 lists 600 V AC.
The three testers at a glance
| Model | ASIN | Method (as listed) | Resistance range (as listed) | Earth voltage (as listed) |
|---|---|---|---|---|
| VIVANTECH Digital Ground Resistance Tester (VA115) | B0GVMWSYH6 | 2-wire and 3-wire | 0.03 to 2000 ohms | AC up to 600 V; DC up to 1500 V |
| VIVANTECH Clamp Ground Resistance Tester (va112) | B0GRVC6XGY | Non-contact clamp, 2-point and 3-point | 0.01 to 500 ohms | Maximum operating voltage 150 volts (specification block) |
| VIVANTECH Earth Ground Tester Kit (VIDY4100) | B0FMX9MT7L | 3-wire and simplified 2-wire | 0 to 2000 ohms | AC 0 to 30 V |
1. VIVANTECH Digital Ground Resistance Tester (VA115)
The VA115 listing supports 2-wire and 3-wire methods, with a range up to 2000 ohms and an accuracy stated as plus or minus 3 percent. The listing gives AC ground voltage up to 600 V and DC solar voltage up to 1500 V. It describes an automatic single-trigger and timed test, with the test stopping when readings settle and an OK or NG prompt shown afterwards. The bullets also list a backlit LCD, data hold, auto power-off, and a low battery indicator.
The safety line reads CAT III 600 V and CAT IV 300 V. The unit weighs 3 pounds and measures 6.8 x 4.9 x 2.7 inches, according to its specification block. The listing says it has an auxiliary ground resistance warning and series interference voltage detection, but it does not say what level triggers either one.
VA115 earth resistance tester on Amazon

2. VIVANTECH Clamp Ground Resistance Tester (va112)
This is the clamp model. Its listing describes a non-contact clamp that measures a ground path without disconnecting the ground leads and without an auxiliary electrode. The bullets give a resistance range of 0.01 to 500 ohms and an AC current measurement of up to 20 A, with the title’s 0.01 to 500 ohm figure matching the bullets. The listing says the tester can store up to 99 groups of measurement data, and it describes an adjustable alarm for resistance or current limits.
The listing names tower grounding, transformer neutral points, substation grounding, telecom rooms and building lightning protection as applications. It supports two-point and three-point methods for isolated electrodes. It powers off after 5 minutes, and a test ring is included for a quick functional check. The specification block gives a maximum operating voltage of 150 volts and a weight of 3.5 pounds. The included parts are listed as the tester, a case and the test ring.
va112 clamp ground resistance tester on Amazon
3. VIVANTECH Earth Ground Tester Kit (VIDY4100)
The kit listing covers two jobs. It measures earth ground resistance from 0 to 2000 ohms, with a stated accuracy of plus or minus 2 percent of reading, and it also reads AC earth voltage from 0 to 30 V. It offers the standard 3-wire method and a simplified 2-wire method for sites where driving auxiliary rods is impractical, such as existing metal pipes or building grounds. The listing describes the casing as dustproof and wet-proof, with an IP54 equivalent rating, and gives an operating range of 0 to 40 degrees Celsius.
The kit includes earth bars, test leads and a tool bag. The leads are listed as 15 m red, 10 m yellow and 5 m green for the 3-wire method, and 1.6 m red and green for the simplified method. Batteries are listed as six AA cells and one 23A 12 V cell. The listing gives an overload protection figure of 300 V AC for one minute on the voltage input, and 200 V AC for 10 seconds on the resistance input.
VIDY4100 earth ground tester kit on Amazon

How we chose these three
We kept products whose listing names an earth ground resistance function with a stated range, and we used only the three extra products that have listing data with a status of ok. The other items in the research set are multimeters, clamp meters and a decibel meter, and their titles do not name an earth or ground tester, so they are not part of this comparison. We did not test any of these testers. Everything below comes from the listing text.
- Method: the VA115 and VIDY4100 list 3-wire methods, and the VIDY4100 and VA115 list a 2-wire method. The va112 lists a non-contact clamp method.
- Range: the two non-clamp models list 2000 ohms as the top limit, while the clamp lists 500 ohms.
- Voltage input: the listings state three different earth voltage figures, which is why the table keeps them separate.
Worked example: a 1,200 ohm reading across the three ranges
Take a reading of 1,200 ohms as an illustration, not a measured value. The va112 clamp lists a top limit of 500 ohms, so 1,200 ohms is outside its range and the listing gives no valid result for that value. The VA115 and the VIDY4100 both list 2000 ohms as the top limit, so 1,200 ohms sits inside both ranges. A 2,400 ohm value would be outside all three listed ranges.
Now take the lead lengths. The kit lists 15 m red, 10 m yellow and 5 m green leads for the 3-wire method, and 1.6 m leads for the simplified 2-wire method. The longest lead in the listing is therefore 15 m. Any run that needs more than 15 m of lead is outside what the kit lists, and the listing does not say whether longer leads are sold separately.
Where the listings disagree
The three listings give three different earth voltage figures, and they are all from the same brand, so the difference is not a matter of different manufacturers.
- VA115: AC ground voltage up to 600 V, with DC solar voltage up to 1500 V.
- va112: maximum operating voltage of 150 volts in the specification block, with no separate AC ground voltage line in the bullets.
- VIDY4100: AC earth voltage 0 to 30 V, and a minimum operating voltage of 30 volts AC in the specification block.
The brand and model fields also differ by listing. The VA115 names its model as VA115 and its part number as VIDY4100A, while the kit is named VIDY4100. Confirm the model you are buying before you compare the figures above.
What the listings do not say
None of the listings gives a resolution or an accuracy figure for the clamp model. The va112 accuracy is not stated in its bullets, so the listing does not support a comparison of accuracy across the three. The VA115 and VIDY4100 give a 3 percent and a 2 percent figure, but the two figures are for different ranges and methods and cannot be compared directly. The listings do not say how far apart the auxiliary rods must sit, or what the stated accuracy means at the low end of each range.
Frequently asked questions
Can the clamp model read a ground path without disconnecting the leads?
The va112 listing says it is a non-contact clamp that needs no disconnection of the ground leads and no auxiliary electrode. The other two listings describe a probe method that uses auxiliary rods.
What is the highest resistance each tester covers?
The VA115 and VIDY4100 list 2000 ohms as the top limit. The va112 clamp lists 500 ohms.
Do the two-wire and three-wire methods need different leads?
The VIDY4100 kit lists long 3-wire leads of 15 m, 10 m and 5 m, and short 1.6 m leads for the simplified 2-wire method. The VA115 lists both methods but does not give lead lengths in its bullets.
How much measurement data does the clamp model store?
The va112 listing says it stores up to 99 groups of measurement data for later review.
Are these testers rated for DC solar voltage?
The VA115 listing gives DC solar voltage up to 1500 V. The va112 and VIDY4100 listings do not describe a DC solar input in their bullets.
Conclusion
All three listings describe an earth ground tester from the same brand, and they split into two families: the clamp model for non-contact work, and the two probe-based models for the 3-wire and 2-wire methods. The VA115 gives the widest voltage and DC solar data, the kit gives a 30 V AC earth voltage figure with a full lead set, and the clamp model gives the only non-contact method. Choose by method and voltage first, and confirm the figures on the live listing before you buy.
For related reading, see best earth ground meter, best earth ground resistance tester, and best soil resistivity meter.
VA115 on Amazon · va112 clamp on Amazon · VIDY4100 kit on Amazon