What Is a Temperature Mode on a Multimeter?

What Is a Temperature Mode on a Multimeter?

As an Amazon Associate we earn from qualifying purchases.

A temperature mode on a multimeter reads a temperature from a thermocouple probe. A thermocouple is two dissimilar metal conductors joined at one end. It produces a small voltage that depends on the temperature at that joined end, and the meter converts that voltage into a temperature reading. The probe is not the same as a voltage or resistance test, and the meter needs a reference point to produce an accurate result.

Quick answer

  • The mode reads a thermocouple, not a live circuit. Connect the probe to the meter’s temperature input or to a converter.
  • The probe generates a small voltage that depends on temperature. The meter or converter turns that voltage into a temperature.
  • Thermocouples measure a difference against a reference junction, and the meter must correct for that reference.
  • Check the probe type and the converter’s stated limits before you measure.

What a thermocouple is

NIST defines a thermocouple as “a pair of dissimilar electrical conductors joined at one end (the measuring junction).” When the other ends are held at a known reference temperature, “the thermoelectric voltage produced by the thermocouple is a repeatable function of the temperature of the measuring junction.” In plain terms, the voltage tells the meter how hot the joined tip is, once the other end is accounted for.

National Instruments Application Note 043 explains that the voltage a thermocouple produces is not a straight line against temperature. The note says the voltage is nonlinear over a wide range, and that over a small range it is approximately linear. This is why a converter or meter uses a conversion table or formula rather than a simple multiplier.

The reference junction

A thermocouple does not report an absolute temperature by itself. NIST defines reference junctions as “those junctions in a thermoelectric circuit that are maintained at a fixed, known temperature, which is often 0 °C.” The name cold junction comes from the traditional practice of holding that reference in an ice bath. The NI note adds that the reference is often measured separately, and that its voltage is then added to the measured voltage. This is called cold-junction compensation.

The Fluke 80TK instruction sheet describes the same idea in its own words: “Thermocouples rely upon the difference in temperature between the measuring junction and a reference junction.” It says the 80TK uses an electronic reference junction rather than an ice bath, and that the converter must be used in a thermal environment consistent with its specifications.

What a converter does

A thermocouple voltage is small, so a converter is often used with a standard multimeter. The Fluke 80TK is a converter of this kind. The sheet states that it “accepts the output of any K-type thermocouple and converts it to 1 millivolt per degree (Celsius or Fahrenheit).” The meter then reads millivolts on a range such as 200, 300 or 400 mV, and the displayed number tracks temperature.

Limits and cautions

The Fluke 80TK sheet gives limits you should read before use. Its ambient operating range is 0 to 50 °C. It states a maximum voltage at the thermocouple input of 60 V DC and 24 V AC. It also says that an open or broken probe gives a steady, constant reading rather than a real temperature, so a fixed number on the display is not proof of a measurement. The sheet also notes that the largest source of error is often the thermal contact between the probe and the surface being measured.

The NI note adds a caution about the reference. If the reference junction temperature is estimated wrongly, the temperature measurement carries that error. Keep the converter or meter at a stable temperature while you measure.

Safety first

A temperature probe is still used around equipment, so treat the work as electrical work too. Work on mains circuits can kill. Do not connect a thermocouple probe into a live circuit as a test lead. The Fluke 80TK limits above apply to the probe input, and they are not a rating for mains work. Before any measurement near wiring, confirm the meter’s CAT rating suits the circuit. Panel and service work belongs to a licensed electrician.

How we chose the sources

This explainer uses the three sources listed at the end of the post. NIST gives the definitions of thermocouple and reference junction. The Fluke 80TK sheet covers one converter and its limits. The NI application note explains the Seebeck voltage, the nonlinear response and cold-junction compensation. Retail listings were not used for any technical statement.

What we could not verify

The sources we opened do not show the temperature setting on every multimeter. They do not say which models have a built-in thermocouple input, and they do not give the accuracy of any specific meter. The Fluke 80TK sheet covers that converter only. For any other meter, the sources do not state its probe type, range or accuracy, so treat those figures as unknown until you read the manual.

FAQ

Does a temperature mode measure temperature without a probe?

In the sources we opened, the temperature reading comes from a thermocouple probe through a converter. The Fluke 80TK sheet describes shorting the converter’s own input terminals to check that it reads the room temperature. That is a converter check, not a measurement of a surface.

What is a Type K probe?

Type K is a common thermocouple type. The Fluke 80TK sheet says the converter accepts “any K-type thermocouple.” Check the probe and the meter or converter manual to confirm they match.

Why does my reading drift?

The NI note says the reference junction must be estimated correctly, and the Fluke sheet names the thermal contact with the surface as the largest source of error. Both can shift a reading.

Can I use this mode to check a live wire?

No. This mode is for a thermocouple probe. A temperature reading does not tell you whether a circuit is safe to touch.

Bottom line

A temperature mode reads a thermocouple probe through a voltage conversion. Match the probe type, respect the stated limits, and use the meter in a stable environment.